Home> Blog> Electric two-way valve is suitable

Electric two-way valve is suitable

May 17, 2023
Specifications: Drive motor: Hysteresis synchronous motor drive Operating voltage: 200VAC, 50Hz / 60Hz (with AC24V, 110V to choose from) Power consumption: ≤ 5.7VA Valve body pressure: 1.6MPa Allowable pressure: ≤ 0.12MPa Applicable medium : Cold water, hot water Medium temperature: 2 ℃ -95 ℃ Ambient temperature: 0 ℃ -60 ℃ Opening and closing time: about 10 seconds, about 5 seconds off Installation and commissioning: Before installation must read the instructions carefully, cut off the power and Must be installed by professional and technical personnel. The flow direction must be the same as the direction of the arrow on the valve body. The valve body must be above the coil water tray to ensure that dripping falls into the water tray. The valve body and actuator must be mounted within ± 60 ° C vertical and at least 30 mm above the space for disassembly. With the surrounding pipelines, equipment, buildings must maintain sufficient space for maintenance operations, must be installed in the maintenance personnel through the manhole to reach the place. The valve body can be installed after pressure test and pressure test. If the actuator is already attached to the valve body, never apply force to the actuator during installation and commissioning as this may damage the actuator. After installation and check the correct, power debugging. At a minimum, observe the three full drive cycles and verify that all components are correct. After passing through the anhydrous test, pass the water test. The system pressure on the water must be strictly controlled within 0.15MPa, to ensure that the electric control valve on the effectiveness of the water switch. Scope of application Air-conditioning, heating, ventilation, domestic hot water and other civil system-level chemicals, petroleum metallurgy, electric light industry Industry production process of automatic control. Search Keyword: More Valve Product Information
Contact Us

Author:

Ms. Lucia Peng

Phone/WhatsApp:

13531888018

Popular Products
You may also like
Related Information
Nippon Electric Co., Ltd. listed new electric torque tester

Nippon Electric Co., Ltd. has listed an electric torque tester that combines the torque meter "TNX" series with the data management function test bench "DSP-10". By combining the...

Electric double eccentric butterfly valve how to choose and installation direction

Electric double eccentric butterfly valve cut off and throttling effect in the pipeline, electric double eccentric butterfly valve opening and closing pieces is a disc-shaped disc, rotating around...

What are the common faults of electric drills? Electric drill repair Daquan

In life, we often encounter accidents like this, for example, our tools are broken. If you buy a new one, it is a bit extravagant; if you let the professional repair it, it will be fine for people to...

Valve technology Large aperture gas medium electric valve new invention

This patent was applied by Beijing Hua Chong Long Run Environmental Technology Co., Ltd., and was authorized notice on March 15, 2017. Description of content The present invention relates to the...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send