Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
About LH-80 hand electric dual-purpose metering pump considerations, I do not know how much we understand? Next, Xiao Bian to give you a good introduction, because this content is still very important, there are some prohibited items absolutely can not do, which involves the security issues. The following is a little more content, I hope we all read it patiently, to remember these precautions. The details are as follows:
1, long-distance transport or long-term unused tanker must be measured before using the motor insulation resistance, the value should not be less than 10 megohms.
2, LH-80 hand electric dual-purpose metering pumps should check the motor steering before work is correct (in the face of the triangular pulley should be clockwise rotation).
3, the gun off, the motor is still driven vane pump suction duration generally not more than 1 minute.
4, in order to maintain the normal efficiency and pressure on the oil, the use of the vane pump on the overflow valve adjustment screw oil pressure regulation.
5, the flow meter on the side of the copper cap to the counter to promote, (referring to 1) 2 flowmeter, each instruction is complete reversible handwheel clockwise, the size of the pointer back to zero. Counting disk pointer automatically back to zero, if you want to continuously count, no longer push the copper cap.
6, control oil gun pinch tight degree, can roughly adjust the amount of oil.
7, measuring the rubber pump rubber cables, wear should be avoided in use, is prohibited pedal roller, in use should always check the rubber case intact.
8, into, out of the oil pipe, oil gun, cable should be around when not in place, can not drag anywhere, into the oil pipe into the sump (or drum) should be cleaned before.
9, rubber cables connected to the power before, should be aware of the ground wire and phase (measured with a multimeter), the ground wire should be connected with the motor chassis, the ground reliable.
10, can not easily produce and accumulate a large number of static nylon tube, plastic tube instead of the machine's special import and export tubing refueling.
11, shall not use ordinary cables instead of the machine dedicated rubber cables and casually removable connection.
12, operators are strictly prohibited to wear chemical fiber clothing for refueling operations, and should comply with the oil and chemical industry safety practices.
13, the operator is strictly prohibited to increase the rated flow, so as to accelerate the accumulation of static electricity, causing danger.
February 13, 2023
November 06, 2021
Nippon Electric Co., Ltd. has listed an electric torque tester that combines the torque meter "TNX" series with the data management function test bench "DSP-10". By combining the...
Electric double eccentric butterfly valve cut off and throttling effect in the pipeline, electric double eccentric butterfly valve opening and closing pieces is a disc-shaped disc, rotating around...
In life, we often encounter accidents like this, for example, our tools are broken. If you buy a new one, it is a bit extravagant; if you let the professional repair it, it will be fine for people to...
This patent was applied by Beijing Hua Chong Long Run Environmental Technology Co., Ltd., and was authorized notice on March 15, 2017. Description of content The present invention relates to the...
Email to this supplier
February 13, 2023
November 06, 2021
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.