Reasons and Treatment Methods of Electric Control Valve Inner Leakage

June 14, 2023
Electric control valve is based on the control of high precision, especially in the flow control, but also in the installation of the structure has obvious advantages, but widely used in industrial control systems, or when we use the electric control valve, or to appear This kind of problem bothers us. Nowadays, the main reason is to explain the causes and treatment methods of electric leakage inside the electric control valve. From the analysis of the causes and solutions of the problems, the maintenance personnel have a good promotion. Electric control valve in the processing or assembly process has received more influence, are likely to cause leakage of the electric control valve, the main problem is the limit switch, mainly due to the limit switch action more fixed, the valve Control of media in the run-time on the regulating valve of the constant erosion and mode, it will lead to the valve closed and lead to internal leakage problems. The emergence of this problem is mainly to adjust the position of the limit switch, you can solve. There are other problems below: 1, regulating valve improper debugging led to internal leakage. 2, due to the electric control valve failure in the control section. Mainly because of the electric valve in the valve limit switches, torque switches and other over, because there is a certain introduction above. As a result of these problems will lead to the sealing surface wear or corrosion or corrosion: mainly in the emergence of trachoma scratches, which is caused by a problem of internal leakage. The emergence of such problems is still mainly in the adjustment efforts. 3, due to the zero setting of the electric actuator is not accurate, this is the result of the valve can not be fully closed. The main method of adjustment: manually close the valve, or manually turn off the valve do not understand the screw in the back half circle, this to adjust the adjustment limit. 4, the valve is pushed down the closure type, if the actuator thrust is not big enough, it will lead to the valve can not be fully closed, which is one of the main problems of internal leakage. The solution: replace the thrust of the implementing agencies, or the balance of spool to reduce the media unbalanced force.
Contact Us

Author:

Ms. Lucia Peng

Phone/WhatsApp:

13531888018

Popular Products
You may also like
Related Information
Nippon Electric Co., Ltd. listed new electric torque tester

Nippon Electric Co., Ltd. has listed an electric torque tester that combines the torque meter "TNX" series with the data management function test bench "DSP-10". By combining the...

Electric double eccentric butterfly valve how to choose and installation direction

Electric double eccentric butterfly valve cut off and throttling effect in the pipeline, electric double eccentric butterfly valve opening and closing pieces is a disc-shaped disc, rotating around...

What are the common faults of electric drills? Electric drill repair Daquan

In life, we often encounter accidents like this, for example, our tools are broken. If you buy a new one, it is a bit extravagant; if you let the professional repair it, it will be fine for people to...

Valve technology Large aperture gas medium electric valve new invention

This patent was applied by Beijing Hua Chong Long Run Environmental Technology Co., Ltd., and was authorized notice on March 15, 2017. Description of content The present invention relates to the...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send