Home> Blog> Siemens electric valve in steam decompression in the efficient use

Siemens electric valve in steam decompression in the efficient use

April 15, 2023
First, the mechanical valve shortcomings: After the boiler output steam, the general high pressure in the pipeline transportation. After reaching the client, it needs to be decompressed for the load to use. At present, most users adopt the installation of mechanical pressure reducing valve on the front of the sub-cylinder. Although this method is simple, there are some shortcomings that can not be overcome and the price of the imported pressure reducing valve is not high. Mechanical pressure relief valve generally has the following disadvantages: 1, the steam load flow or no flow case back-end steam pressure will gradually rise, can not maintain the set pressure. 2, the condensate in the pipeline more circumstances, there will be unreliable movements. 3, the pressure setting adjustment is not intuitive, inconvenient, in the case of higher installation position, according to changes in load demand is not easy to adjust, can not be adjusted remotely. 4, can not turn off steam automatically. Some loads in the power outage or safety potential need immediate stop steam, mechanical pressure reducing valve can not do it. 5, mechanical pressure reducing valve pressure regulating range is limited, some of the pressure requirements are particularly low load can not meet the requirements. 6, higher failure rate. Easy to appear capillary or balance hole blockage, membrane deformation, rupture, leakage and so on. Second, the Siemens electric valve in the steam decompression in the efficient use of: In view of the above problems, I specifically designed the Siemens steam electric valve steam decompression program, the use of this program for steam pressure regulation implementation two years of stable operation, there have been Fault, a good solution to the above failure. Specific programs are as follows: 1, the pipeline connection diagram components list: ① P steam source ② SF123 manual stop valve ③ GLQ filter ④ DF Siemens electric steam valve VVF45.504 ⑤ P123 pressure gauge ⑥ FQG steam sub-cylinder ⑦ L123 steam load 2, the components list: ① K1 circuit breaker 2P5A ② K2 circuit 1P3A ③ KZQ digital loop regulator RKCCD901 ④CGQ pressure sensor Siemens OBE2000-P16 ⑤ T Transformer 220VAC / 24VAC150AV⑥ZXQ electric valve actuator Siemens SKD65 3, RKC controller parameter settings ①, PID can only be manually set according to the actual load, but also automatic calculation (ATU Function completed. ②, SL1 input type selection voltage 0 ~ 5V voltage input (1110). ③, SL4 The first alarm mode selection uses the upper deviation alarm (0001). ④, SL6 control output type selection 4 ~ 20mA continuous output (0111). ⑤, SL7 alarm relay status selection is set to 01, that is, when the alarm 1 alarm NC has become NO. ⑥, SLH set the maximum measurement range of 8.00, which corresponds to 0.8Mpa. ⑦, SLL set the lower limit of the measurement range of 0.00, which corresponds to 0Mpa. ⑧, PGDP set to 2 decimal places. ⑨, other parameters can use the default value. 4, Matters needing attention ①, pay attention to the choice of electric valve actuator to reference steam pressure and set pressure, actuator size and pressure to match the size, otherwise, may be lax or open. ②, the pressure sensor should be installed in the sub-cylinder, there must be a bend and a section of the export pipe, to avoid the impact of the sensor and the temperature is too high, reducing service life. ③, 4 ~ 20mA control signal into the AL1 and then to the actuator is in the pressure relative to the set value is too high, when the alarm value exceeds the AL1 action disconnect the control signal to fully close the motor valve. ④ The existing settings SL1, SLH, SLL determine the measurement range between 0 ~ 8Mpa, the sensor can measure to 1.6Mpa, if you need a larger measuring range, the need to convert the input signal through an external line, and the SLH, SLL set again. ⑤, the measurement shows a slight error can be calibrated by PB value. The program pressure shows that the settings directly on the controller, the adjustment easy to use, small pressure fluctuations, reliable operation, to save steam energy consumption also has some help. Siemens steam electric valve price is slightly lower than the imported mechanical valve, is a way worth promoting. The disadvantage is that you must need power, no power can not be used.
Contact Us

Author:

Ms. Lucia Peng

Phone/WhatsApp:

13531888018

Popular Products
You may also like
Related Information
Nippon Electric Co., Ltd. listed new electric torque tester

Nippon Electric Co., Ltd. has listed an electric torque tester that combines the torque meter "TNX" series with the data management function test bench "DSP-10". By combining the...

Electric double eccentric butterfly valve how to choose and installation direction

Electric double eccentric butterfly valve cut off and throttling effect in the pipeline, electric double eccentric butterfly valve opening and closing pieces is a disc-shaped disc, rotating around...

What are the common faults of electric drills? Electric drill repair Daquan

In life, we often encounter accidents like this, for example, our tools are broken. If you buy a new one, it is a bit extravagant; if you let the professional repair it, it will be fine for people to...

Valve technology Large aperture gas medium electric valve new invention

This patent was applied by Beijing Hua Chong Long Run Environmental Technology Co., Ltd., and was authorized notice on March 15, 2017. Description of content The present invention relates to the...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send